<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="../PSD_R2x3.xsl"?>
<PropertySetDef><IfcVersion version="2x3 TC1" schema="IfcProductExtension"/><Name>Pset_SpaceLightingRequirements</Name><Definition>Definition from IAI: Properties related to the lighting requirements that apply to the occurrences of IfcSpace or IfcZone. This includes the required artificial lighting, illuminance, etc.</Definition><Applicability>IfcSpace, IfcZone entity.</Applicability><ApplicableClasses><ClassName>IfcSpace</ClassName><ClassName>IfcZone</ClassName></ApplicableClasses><ApplicableTypeValue></ApplicableTypeValue><PropertyDefs><PropertyDef><Name>ArtificialLighting</Name><PropertyType><TypePropertySingleValue><DataType type="IfcBoolean"/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>Indication whether this space  requires artificial lighting (as natural lighting would be not sufficient). (TRUE) indicates yes (FALSE) otherwise.</Definition></PropertyDef><PropertyDef><Name>Illuminance</Name><PropertyType><TypePropertySingleValue><DataType type="IfcIlluminanceMeasure"/><UnitType type="ILLUMINANCEUNIT"/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>Required average illuminance value for this space.</Definition></PropertyDef></PropertyDefs></PropertySetDef>