<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="../PSD_R2x3.xsl"?>
<PropertySetDef><IfcVersion version="2x3 TC1" schema="IFCPRODUCTEXTENSION"/><Name>Pset_SpaceThermalDesign</Name><Definition>Definition from IAI: Space or zone HVAC design requirements. HISTORY: New property set in IFC Release 1.0 (Pset_SpaceHvacInformation); renamed to Pset_SpaceThermalDesign and revised in IFC2x2.</Definition><Applicability>Entity common property set</Applicability><ApplicableClasses><ClassName>IfcSpace</ClassName></ApplicableClasses><ApplicableTypeValue></ApplicableTypeValue><PropertyDefs><PropertyDef><Name>CoolingDesignAirflow</Name><PropertyType><TypePropertySingleValue><DataType type="IfcVolumetricFlowRateMeasure"/><UnitType type="VOLUMETRICFLOWRATEUNIT"/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>The air flowrate required during the peak cooling conditions. </Definition></PropertyDef><PropertyDef><Name>HeatingDesignAirflow</Name><PropertyType><TypePropertySingleValue><DataType type="IfcVolumetricFlowRateMeasure"/><UnitType type="VOLUMETRICFLOWRATEUNIT"/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>The air flowrate required during the peak heating conditions, but could also be determined by minimum ventilation requirement or minimum air change requirements. </Definition></PropertyDef><PropertyDef><Name>TotalSensibleHeatGain</Name><PropertyType><TypePropertySingleValue><DataType type="IfcPowerMeasure"/><UnitType type="POWERUNIT"/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>The total sensible heat or energy gained by the space during the peak cooling conditions. </Definition></PropertyDef><PropertyDef><Name>TotalHeatGain</Name><PropertyType><TypePropertySingleValue><DataType type="IfcPowerMeasure"/><UnitType type="POWERUNIT"/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>The total amount of heat or energy gained by the space at the time of the space's peak cooling conditions. </Definition></PropertyDef><PropertyDef><Name>TotalHeatLoss</Name><PropertyType><TypePropertySingleValue><DataType type="IfcPowerMeasure"/><UnitType type="POWERUNIT"/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>The total amount of heat or energy lost by the space at the time of the space's peak heating conditions. </Definition></PropertyDef><PropertyDef><Name>CoolingDryBulb</Name><PropertyType><TypePropertySingleValue><DataType type="IfcThermodynamicTemperatureMeasure "/><UnitType type="THERMODYNAMICTEMPERATUREUNIT"/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>Inside dry bulb temperature for cooling design </Definition></PropertyDef><PropertyDef><Name>CoolingRelativeHumidity</Name><PropertyType><TypePropertySingleValue><DataType type="IfcPositiveRatioMeasure "/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>Inside relative humidity for cooling design. </Definition></PropertyDef><PropertyDef><Name>HeatingDryBulb</Name><PropertyType><TypePropertySingleValue><DataType type="IfcThermodynamicTemperatureMeasure "/><UnitType type="THERMODYNAMICTEMPERATUREUNIT"/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>Inside dry bulb temperature for heating design </Definition></PropertyDef><PropertyDef><Name>HeatingRelativeHumidity</Name><PropertyType><TypePropertySingleValue><DataType type="IfcPositiveRatioMeasure "/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>Inside relative humidity for heating design. </Definition></PropertyDef><PropertyDef><Name>VentilationAirFlowrate</Name><PropertyType><TypePropertySingleValue><DataType type="IfcVolumetricFlowRateMeasure"/><UnitType type="VOLUMETRICFLOWRATEUNIT"/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>Ventilation outside air requirement for the space. </Definition></PropertyDef><PropertyDef><Name>ExhaustAirFlowrate</Name><PropertyType><TypePropertySingleValue><DataType type="IfcVolumetricFlowRateMeasure"/><UnitType type="VOLUMETRICFLOWRATEUNIT"/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>Design exhaust air flow rate for the space. </Definition></PropertyDef><PropertyDef><Name>CeilingRAPlenum</Name><PropertyType><TypePropertySingleValue><DataType type="IfcBoolean "/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>Ceiling plenum used for return air or not. TRUE = Yes, FALSE = No. </Definition></PropertyDef><PropertyDef><Name>BoundaryAreaHeatLoss</Name><PropertyType><TypePropertySingleValue><DataType type="IfcHeatFluxDensityMeasure"/><UnitType type="HEATFLUXDENSITYUNIT "/></TypePropertySingleValue></PropertyType><ValueDef/><Definition>Heat loss per unit area for the boundary object. This is a design input value for use in the absence of calculated load data. </Definition></PropertyDef></PropertyDefs></PropertySetDef>